4KW Belt Power System For Ford environmental monitoring vehicle
◆Tech Data Of Belt Power Alternator | Belt Power System Model : S4CT4000-FORD-V348 | ||||||
Belt Alternator | Vehicle Speed , Output Current , Output Power | { Need 1 belt power motors in this system } | Controler Model | ||||
S4C4000TD | Vehicle Speed | 750 RPM {when parking} | 1000 RPM | 1300 RPM | 1600 RPM | 2000 RPM {when driving} | S4C4000-4U-220 |
Alternator Voltage | Output Current | 71.5A | 80A | 88A | 90A | 96A | Controler Style |
DC 56 V | Output Power | 4.0KW | 4.5KW | 4.9KW | 5.0KW | 5.4KW | 4U Standard Cabinet |
working temperature : -40℃ — +100℃; storage temperature : -40℃ — +70℃; relative humidity : 95±3% (at +40℃) | |||||||
Meet the standard : GJB150.9A-2019 (humid) GJB150.10A-2019 (mould) GJB150.11A-2019 (salt spray) GJB150.16A-2019 (vibration) GJB150.18A-2019 (impact) |
◆Tech Data Of The Electrical System | Choose according to the actual situation | |||||||||||
output voltage |
frequency |
voltage stability time |
frequency adjustment |
transient frequency adjustment |
frequency stabilization time |
frequency volatility |
remote monitoring |
Power Battery Specifications | Single Power Battery Shapes | |||
Capacity | QTY | Length | Width | Height | ||||||||
220V(±0.5%) | 50±1HZ | ≤1S | ±2% | ±4% | ≤3S | ±1% | optional | 38AH | 4 | 197 | 165 | 170 |
Service Promise : one year warranty |